| Customization: | Available |
|---|---|
| Certification: | CE, Awta |
| Thickness: | 0.3mm-0.8mm |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Criteria | Reference | Result | Requirement |
Flammability Index | AS 1530.2-1993 | Lows5 | High (> 5)/Low(≤5) |
Nominal Thickness | AS2001.2.15-1989 | 0.17 mm | <1 mm |
Duty | AS/NZS 4200.1:2017 | Extra Heavy | Classification |
Tensile Strength Machine Direction | AS1301.448s-91 | 14.5kN/m | Min 13N |
Tensile Strength Lateral Direction | AS1301.448s-91 | 12.5kN/m | Min 10.5N |
Edge Tear Machine Direction | ASNZS 4200.1-2017 | 525N | Min 90 N |
Edge Tear Lateral Direction | ASNZS 4200.1-2017 | 409/N.s | Min 90N |
Vapour Control | ASTM E96 | Class 2 Vapour Permeable | Class 1 to 4 |
Vapour Permeance | ASTM E96 | 4.837μg/N.s | Value |
Water Control | AS/NZS 4201.4:1994 | Water Barrier | Classification |
Air Control | AS/NZS 4200.1:2017 | Air Barrier | Classification |
Resistance to DryDelamination | AS/NZS 4201.1:1994 | Pass | Pass |
Resistance toWetDelamination | AS/NZS 4201.2:1994 | Pass | Pass |
Shrinkage (Repeated wetting & drying) | AS/NZS 4201.3:1994 | 0.2% | < 0.5% |
Electrical Conductivity | AS/NZS 4200.1:2017 | Non-conductive | Classification |
Emittance Value | AS/NZS 4201.5:1994 | Anti-glare side: 0.9, Foil side: 0.77 | Value |
Emittance Classification | AS/NZS 4200.1:2017 | IR Non-reflective.IR Non-reflective | Classification |

Type | Breathable roofing membrabe |
Material | PE PP |
Width | 1.5 m or as your requirement |
Length | 50 m or as your requirement |
Sd value | 0.02 m (-0.005/+0.015) |
Water tightness | W1 |
Resistance to UV | 3month , 6month |